Khalid A B Ali's profile

Modelling of Solenoide Operated Piston Pump

Solenoid Piston Pump
Indicated selective half-section
Assembly Cross-Section
The main objective of the project is to optimise the current (GOTEC ® EMX-08) pump to meet medical applications requirements. In order to present the design intent this section will describe the principle of operation and its effect on the 3D CAD models. Below are the new design characteristics:

Electrical characteristics

Voltage: ~230 [V]
Current: 13 [A]
Power : 18 [W]
Frequency: 50 [Hz]
C8 power inlet IEC320
AC half-wave rectification
Class F coil with class 1 insulation
 
Pump characteristics

50­±5 L/min
Liquid  temperature 20-40 0C
Self-priming [0.5 - 3.0 m]
OD 7 [mm] connections for soft tubing
 
Other characteristics

Chemical resistance
Small and compact
Light weight ~ 100 [g][1]
Maintenance free
Long lifetime
 


[1] Not including DIN diode
Principle of Operation
Detailed prospective view of piston wall interferance 
Piston-Seal
Inlet - Pressure Chamber - outlet
Inlet valve arrangement 
Body Cast
 
Modelling of Solenoide Operated Piston Pump
Published:

Modelling of Solenoide Operated Piston Pump

This project aimed to improve the design of GOTEC’s ® EMX-08 solenoid piston pump, to fit medical application purposes. Challenging deliverables Read More

Published: